# RMP-MSK-005 Exercise form monitoring by camera: consent-first live view and the exercise specialists' form checklist, with no scoring of the crew
# Version 0.2 (Draft). CONCEPTUAL. NOT FOR CLINICAL USE.
# Space Medicine Foundation robot-readable protocol library. Format: https://spacemedicinefoundation.org/robotic-medicine/protocols/schema/
# Every threshold marked <set by ...> must be set by the named owner (see the schema) before any use.
schema_version: '0.3'
version: '0.2'
status: draft
conceptual: true
not_for_clinical_use: true
max_autonomy: 2
missions:
- leo
- commercial
- moon
- mars
updated: '2026-10-21'
review:
  state: reviewed-ai-assisted
  requested: '2026-10-21'
  human_clinician_review: false
  text: >-
    AI-assisted clinical and source review by the Medical Research Assistant, Oct 21, 2026 (batch 12 review:
    15 required corrections, R1 to R15; 11 optional suggestions not applied in this version); all required
    corrections that apply to this protocol are applied in this version (see Corrections). No named human
    clinician has reviewed it. Not for clinical use.
  reviewed: '2026-10-21'
fixed_rules:
  flight_surgeon_is_medical_authority: true
  cmo_acts_under_delegated_care: true
  human_starts_and_restarts_robot: true
  robot_never_diagnoses: true
  no_drug_or_fluid_advice_by_robot: true
  safe_state_on_fault_or_no_response: true
  lost_link_pause_then_cmo_decides: true
robot_lockouts:
  diagnosis: true
  drug_or_fluid_advice: true
  starting_stopping_or_adjusting_oxygen_or_any_medicine: true
  self_start_or_self_restart: true
  changing_own_protocol_thresholds_or_limits: true
  handing_over_a_mismatched_item_as_verified: true
id: RMP-MSK-005
slug: rmp-msk-005
title: >-
  Exercise form monitoring by camera: consent-first live view and the exercise specialists' form checklist,
  with no scoring of the crew
category: msk
tier: 3
rung_note: >-
  Max rung 2: the robot positions a camera at a set viewpoint outside the exercise device's moving envelope,
  shows the live view and the form checklist to the crewmember, and records clips only with consent. It
  never scores, measures or compares anyone, never adjusts the device, and "Contact with the crewmember:
  not allowed".
result_language:
  use:
  - clip recorded
  - camera off
  - as stated by the crewmember
  - sent to the exercise specialists
  - non-diagnostic, for human review
  never:
  - normal
  - no problem found
  - all clear
  - negative
  - any diagnosis or cause
  - good form
  - bad form
  - correct
  - incorrect
  - improving
  - worse
  - score
  - grade
  - rating
  - rank
  - pass
  - fail
  - better than
  - compared with
  - injury-free
  - fit for duty
  - safe
  - mild
  - minor
scope:
  summary: >-
    On a crewmember's command, or when the crewmember accepts the on-screen prompt at an exercise session
    the exercise specialists scheduled, the robot asks for consent before any camera use, places its camera
    at the viewpoint the exercise specialists set for that device, and shows the live view and their written
    form checklist on the crewmember's own screen. Clips are recorded only if the crewmember agrees, and
    go only to the people the crewmember agrees to. No scoring of any kind: the robot gives no score,
    grade, rating, rank, pass or fail, and no comparison between crewmembers or with earlier sessions;
    it measures nothing from the video (no joint angles, repetition counts, speed or symmetry) and never
    says form is good, bad or improving. Form feedback comes only from the human exercise specialists
    or the CMO. Any pain or injury moves to the matching care protocol.
  why: >-
    Exercise is the most frequent source of injuries in astronauts living aboard the ISS (Scheuring 2009:
    0.003 exercise-related injuries per day), and NASA-STD-3001 requires exercise countermeasures for
    bone, muscle and aerobic fitness (V2 7038). A live view with the exercise specialists' own checklist
    lets the crewmember see their form, and clips let the human specialists give feedback. Automatic scoring
    is excluded by the protocol owner's brief ("allow no scoring of the crew"): scores or comparisons
    could be used to judge crewmembers, are not validated for clinical use, and would add a privacy risk.
    The viewpoint, framing rules and consent steps are design judgment. Open question for review: whether
    clips should be recorded at all, or the view kept live only.
  covers:
  - Camera view and form checklist during scheduled or on-command exercise sessions
  - Clips recorded only with consent, for the exercise specialists and the flight surgeon
  - 'Pain or injury during exercise: RMP-MSK-001; chest pain: RMP-CARD-002'
  locked_out:
  - Diagnosis or naming a cause
  - Any medicine, fluid or oxygen advice; starting, stopping or adjusting oxygen
  - Touching the crewmember
  - >-
    Handing over any medicine outside RMP-PHARM-001, or after a MISMATCH or CANNOT VERIFY (the item stays
    quarantined; only the CMO can ask for it, through the RMP-PHARM-001 logged two-step override)
  - >-
    Scoring, grading, rating, ranking or comparing crewmembers, or comparing a crewmember with earlier
    sessions
  - >-
    Measuring anything from the video (joint angles, repetition counts, speed, symmetry) or running pose-estimation
    software
  - Saying that form is good, bad, correct or improving
  - Adjusting, loading or stopping the exercise device, or moving into its moving envelope
  - Any camera use without consent for that session, or with another crewmember in frame
  - >-
    Showing video on a shared display, or using it to assess, rank or select crewmembers, or for robot
    or AI training, research or outreach without separate written consent
  - Camera use in a hygiene area or sleep station
  related:
  - RMP-MSK-001
  - RMP-CARD-001
  - RMP-CARD-002
  - RMP-INF-002
roles:
  medical_authority: Flight surgeon (ground). Holds medical authority for every run.
  onboard_lead: >-
    Crew medical officer (CMO), acting under delegated care; uses the pre-approved onboard checklist when
    there is no link.
  others:
  - 'Second trained CMO: receives every alert and takes over if the CMO is the patient'
  - 'Vehicle commander: leads any cabin emergency procedure'
  - 'Other crew: help as the CMO or commander directs'
  - >-
    Exercise specialists (ground strength and conditioning specialists working with the flight surgeon):
    set the form checklist and the camera viewpoint, and review clips the crewmember shares
  robot_may:
  - Ask for consent before any camera use
  - Place its camera at the set viewpoint outside the device's moving envelope
  - Show the live view and the form checklist to the crewmember
  - Record and label clips with consent
  - Alert the CMO and flight surgeon to a red flag
  robot_may_not:
  - Score, measure, rank or compare anyone
  - Touch anyone or the exercise device
  - Record without consent or with another crewmember in frame
  - Start a scheduled session without a human accepting the prompt
  commercial: >-
    On commercial flights, 'flight surgeon' and 'CMO' mean the operator's designated medical authority
    and trained onboard responder. If no trained responder is aboard, this protocol is not used. (NASA-STD-3001
    requires two CMOs per vehicle for NASA programs [V1 3006]; FAA rules set no medical standards for
    spaceflight participants.)
preconditions:
- id: PRE-1
  text: >-
    The form session starts only when the crewmember (or the CMO) accepts the on-screen prompt; a loaded
    schedule alone never starts it. An unaccepted prompt is logged privately as "not accepted"; it is
    never reported to the CMO or the exercise specialists, and never counted. A crewmember or the CMO
    can also start it by command.
  check: human_start == true
  refs:
  - V2 10174
- id: PRE-2
  text: Robot self-test passed; kit stowage locations known.
  refs:
  - V2 10161
  - V2 7059
- id: PRE-3
  text: Robot and supplies restrained when not moving.
  refs:
  - V2 7046
- id: PRE-4
  text: Link status known. The crew never wait for the robot before acting.
  check: link_state in [live, delayed, down]
consent:
  standard: >-
    Before the camera turns on, the crewmember agrees to the camera for this session and chooses live
    view only, or live view with clips. Clips go only to the people the crewmember agrees to. The microphone
    stays off and clips have no audio unless the crewmember agrees to audio. Declining, or not accepting
    a session, is logged privately and never reported or counted.
  emergency: >-
    There is no emergency use of the camera in this protocol: a red flag sends an alert, and the camera
    stays as it was or turns off.
  withdrawal: >-
    The crewmember can turn the camera off or stop recording at any time by voice or on screen; clips
    already taken can be deleted at the crewmember's request unless the flight surgeon holds them for
    an injury report.
inputs:
- id: IN-1
  name: Form checklist and camera viewpoint for each device, set by the exercise specialists
  source: Exercise specialists
  required: true
  if_missing: The robot shows "checklist not loaded"; live view only, on the crewmember's command.
- id: IN-2
  name: Consent for this session (live only, or live with clips)
  source: Crewmember
  required: true
  if_missing: Camera stays off.
- id: IN-3
  name: Symptoms in the crewmember's words (pain, a pop, chest pain, feeling faint)
  source: Crewmember
  required: false
  if_missing: Log "no response"; D3 applies.
- id: IN-4
  name: Link status and delay
  source: Communications system
  required: true
  if_missing: Treat as link down; clips are stored and forwarded.
steps:
- id: S1
  actor: robot
  rung: 2
  action: >-
    Once the crewmember accepts, log that a form session has started (sent to the flight surgeon with
    the next package; URGENT only if a red flag is stated). The form session starts only when the crewmember
    (or the CMO) accepts the on-screen prompt; a loaded schedule alone never starts it. An unaccepted
    prompt is logged privately as "not accepted"; it is never reported to the CMO or the exercise specialists,
    and never counted. A crewmember or the CMO can also start it by command. Every URGENT alert goes to
    the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link is down).
    If the CMO is the patient, is busy treating, or does not answer, the alert goes to the second trained
    CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not acknowledged within
    <set by validation> seconds is repeated and sent to the next named crewmember.
  success: Notice logged; prompt accepted or "not accepted" logged.
  refs:
  - V2 10174
  - V1 3006
- id: S2
  actor: robot
  rung: 2
  action: >-
    Before the camera turns on, ask the crewmember on screen whether they agree to the camera for this
    session, and whether they want live view only or live view with clips. With no clear yes, the camera
    stays off and only the checklist is shown. The microphone stays off, and clips have no audio, unless
    the crewmember agrees to audio for this session.
  success: Consent logged, or camera off.
  refs:
  - V1 7003
- id: S3
  actor: robot
  rung: 2
  action: >-
    Move to the viewpoint the exercise specialists set for the device, outside the device's moving envelope
    and the keep-out zone, and aim the camera only at the device area. Show the live view and the form
    checklist only on the crewmember's own screen. No scoring of any kind: the robot gives no score, grade,
    rating, rank, pass or fail, and no comparison between crewmembers or with earlier sessions; it measures
    nothing from the video (no joint angles, repetition counts, speed or symmetry) and never says form
    is good, bad or improving. Form feedback comes only from the human exercise specialists or the CMO.
  success: Live view and checklist shown; robot outside the envelope.
  limit: <set by validation>
  refs:
  - V2 10172
  - V2 7038
- id: S4
  actor: crew
  action: >-
    The crewmember exercises as the exercise prescription states and can turn the camera off, stop or
    pause at any time. The CMO or exercise specialists give any form feedback.
  success: Session done or stopped.
  refs:
  - V2 7038
- id: S5
  actor: robot
  rung: 2
  action: >-
    If the crewmember chose clips, record only when they ask, and label each clip with the device, exercise,
    date and clock time, marked "non-diagnostic, for human review". If anyone else comes into frame, stop
    recording at once. Clips are stored only in the crewmember's medical record, encrypted in storage
    and in transit as the program requires; access is limited to the crewmember, the CMO, the flight surgeon
    and the exercise specialists the crewmember agrees to. They are never shown on a shared display, never
    used for robot or AI training, research or outreach without separate written consent, and never used
    to assess, rank or select crewmembers.
  success: Clips labelled and stored, or none.
  refs:
  - V1 7003
- id: S6
  actor: robot
  rung: 2
  action: >-
    Ask the crewmember on screen or by voice whether they had any pain, a pop, chest pain or felt faint,
    and log the answers word for word.
  success: Answers logged or "no response".
  refs:
  - V1 6003
- id: S7
  actor: robot
  rung: 2
  action: >-
    After any URGENT alert: After an URGENT alert the robot does not leave on its own: it stays at its
    rest position in the module, with its screen and voice link available, until a human has taken over
    or tells it to go. It never follows, blocks or touches anyone. It keeps time-stamping what humans
    say they did, and repeats the alert if it is not acknowledged.
  success: Robot at rest in the module until a human releases it; alert acknowledged or escalated.
  refs:
  - V2 10173
  - V1 3006
- id: S8
  actor: ground
  action: >-
    The exercise specialists review clips the crewmember shared and give feedback through the crewmember's
    usual channel; the flight surgeon (or the CMO under the onboard checklist when there is no link) decides
    on any symptom.
  success: Feedback or decision logged.
  refs:
  - V1 3003
- id: S9
  actor: robot
  rung: 2
  action: >-
    Send the flight surgeon one package for each session the crewmember ran with the camera: session times,
    answers as stated, alerts and decisions (a declined or unaccepted session is never in it); clips go
    only to the people the crewmember agreed to.
  success: Package delivered or queued.
  refs:
  - V1 6003
  - V1 7003
decisions:
- id: D1
  after: S2
  decided_by: robot
  question: 'Before the camera turns on: did the crewmember agree to the camera for this session?'
  branches:
  - if: Yes, live view only
    then: Camera on for live view; no recording.
  - if: Yes, live view with clips
    then: Camera on; clips only when the crewmember asks (S5).
  - if: No, or no clear answer
    then: >-
      Camera stays off; the checklist is shown on screen only; "camera declined" is logged privately and
      is never reported to the CMO or the exercise specialists, or counted.
- id: D2
  after: S6
  decided_by: robot
  question: >-
    Checked after every answer and at any point in the run (even mid-question or mid-step): does any answer,
    reading or observation meet a red flag?
  branches:
  - if: 'Yes'
    then: >-
      Stop the current question or step at once and apply the action listed for each matching red flag
      (URGENT alert, flag, or stop), with the answer or reading itself, never a cause. Every URGENT alert
      goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link
      is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the
      second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not
      acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
  - if: 'No'
    then: Continue.
- id: D3
  after: S6
  decided_by: robot
  question: Did the crewmember answer the symptom question, or say they want to skip it?
  branches:
  - if: 'Yes'
    then: Continue.
  - if: Declined explicitly (the crewmember says no to a question)
    then: Log "declined" for that question only; the alert already sent stands.
  - if: No response, or the answer does not make sense
    then: >-
      URGENT: log "no response" (never "declined"); the CMO, or the second trained CMO if the CMO is the
      patient, checks the crewmember in person at once.
- id: D4
  after: S8
  decided_by: ground
  question: What feedback or care applies?
  branches:
  - if: Link live
    then: Flight surgeon decides; robot logs.
  - if: Link down or delay too long
    then: >-
      The CMO decides under the pre-approved onboard checklist; the flight surgeon reviews the log at
      the next contact.
stop_rules:
- id: X1
  trigger: The patient (or the crewmember being examined) says stop, or withdraws consent
  action: >-
    Robot stops all motion at once, backs away to its rest position and tells the CMO. Recording stops
    unless the patient agrees to keep it running.
  level: stop
  refs:
  - V2 10165
- id: X2
  trigger: Any crewmember presses stop or takes over control
  action: Protective stop; robot holds its stopped position; only a human may restart it.
  level: safe-state
  refs:
  - V2 10165
  - V2 10168
  - V2 10174
- id: X3
  trigger: Robot fault, sensor fault, or a force, speed or reach limit is reached
  action: Protective stop and hand control to the CMO; log the fault.
  level: safe-state
  refs:
  - V2 10172
  - V2 10168
- id: X4
  trigger: CMO is asked to take over and does not respond (for example, the CMO is the patient)
  action: Robot stays stopped; the next named crewmember is called.
  level: safe-state
  refs:
  - V2 10173
  - V2 7045
- id: X5
  trigger: Loss of link, or delay longer than the limit for live guidance
  action: >-
    Only the robot pauses: before it holds, it moves to a position clear of a hatch route or a crewmember's
    route (it never pauses in one), and tells the CMO. This pauses robot movement only: crew exercise,
    care already under way and all other care continue under the onboard checklist and never wait for
    the link or the robot. The CMO decides whether the robot continues offline under the pre-approved
    onboard checklist; it resumes only on the CMO's confirmation.
  level: pause
  refs:
  - V2 10172
  - V2 10173
- id: X6
  trigger: An URGENT alert is not acknowledged within the set time
  action: >-
    Robot repeats the alert and sends it to the next named crewmember (the second trained CMO first if
    the CMO is the patient), and keeps repeating at the set interval. It stays where it is: it does not
    leave on its own.
  level: urgent
  refs:
  - V1 3006
  - V2 10173
- id: X7
  trigger: The crewmember stops responding, or seems confused or drowsy, at any point
  action: >-
    URGENT alert at once, even mid-question or mid-step; the robot stops its current task, stays at its
    rest position and does not continue the run; a crewmember checks in person.
  level: urgent
- id: X8
  trigger: A crewmember asks the robot what is wrong, or for medicine, fluid or treatment advice
  action: >-
    Robot declines, says it cannot assess or advise, and routes the question to the CMO or flight surgeon.
  level: stop
- id: X9
  trigger: The crewmember asks to turn the camera off, or another crewmember comes into frame
  action: >-
    Robot turns the camera off or stops recording at once and logs it; a clip with someone else in frame
    is held unsent and flagged to the flight surgeon, who decides whether to keep it.
  level: stop
  refs:
  - V1 7003
- id: X10
  trigger: The device moves toward the robot, or the crewmember needs the space the robot is in
  action: >-
    Robot moves clear at once without contact and holds; it never touches the device or the crewmember
    and never pauses in a hatch route.
  level: safe-state
  refs:
  - V2 10172
red_flags:
- id: RF1
  sign: Chest pain, or pain spreading to the arm, jaw or back, during or after exercise, as stated
  threshold: any
  action: URGENT alert; see RMP-CARD-002
  source: gulati
- id: RF2
  sign: Unresponsive, or not breathing normally
  threshold: any
  action: URGENT alert; start RMP-CARD-001 now
  source: aha2025bls
- id: RF3
  sign: >-
    Sudden severe back or neck pain, or pain with numbness, tingling or weakness in an arm or leg, as
    stated
  threshold: any
  action: URGENT alert; see RMP-MSK-001
  source: johnston
- id: RF4
  sign: Pain, a pop, a strain or any injury during exercise, as stated
  threshold: any
  action: Flag to the CMO and flight surgeon; see RMP-MSK-001
  source: scheuring2009
- id: RF5
  sign: >-
    Feeling faint, light-headed or unusually short of breath during exercise, as stated (design judgment)
  threshold: any
  action: URGENT alert; the CMO checks in person
- id: RF6
  sign: >-
    A harness, cable, bungee or load fault on the exercise device, as stated or announced by the device
    (design judgment)
  threshold: any
  action: 'Stop: the robot asks the crewmember to stop using the device and tells the CMO and commander'
safety_limits:
- id: L1
  name: Contact with the crewmember
  value: not allowed
  enforced: Keep-out zone in the robot controller
  refs:
  - V2 10172
- id: L2
  name: Scoring, measuring, ranking or comparing crewmembers from video
  value: not allowed
  enforced: No such function is loaded; video is only displayed and, with consent, stored
  refs:
  - V1 7003
- id: L3
  name: Robot inside the exercise device's moving envelope
  value: not allowed
  enforced: Keep-out map in the robot controller
  refs:
  - V2 10172
- id: L4
  name: >-
    Video shown on a shared display, or used to assess, rank or select crewmembers, or for robot or AI
    training, research or outreach without separate written consent
  value: not allowed
  enforced: Clips stored only in the medical record
  refs:
  - V1 7003
- id: L5
  name: Robot speed near the crewmember
  value: <set by validation>
  enforced: Hard limit in the controller
  refs:
  - V2 10172
logs:
- id: LOG-1
  text: Every input, robot action, decision (with who made it) and hand-off, time-stamped to the second.
  refs:
  - V2 10163
  - V2 10164
- id: LOG-2
  text: Mode changes and safety-limit events are announced to the operator as they happen and logged.
  refs:
  - V2 10162
  - V2 10172
- id: LOG-3
  text: >-
    Records are stored and sent as private medical data, encrypted, with access limited to the medical
    team.
  refs:
  - V1 6003
  - V1 7003
- id: LOG-4
  text: Results are kept in a permanent, retrievable format so the flight surgeon can see trends.
  refs:
  - V1 7001
- id: LOG-5
  text: >-
    Session start and prompt acceptance; consent choice; each clip with device, exercise, date and time;
    clips stopped because someone came into frame; answers as stated; who viewed the clips. No scores
    or measurements are logged.
- id: LOG-6
  text: >-
    Each URGENT alert, who received it, the time it was acknowledged (or the escalation to the next named
    crewmember), and the time a human released the robot.
  refs:
  - V2 10163
requirements:
- id: V1 3003
  use: In-mission preventive health care and monitoring of physiological and psychosocial well-being.
- id: V1 3006
  use: >-
    Two trained CMOs per vehicle for NASA programs; the second trained CMO receives alerts when the CMO
    is the patient (see the commercial-flight note).
- id: V1 6003
  use: Logs and alerts sent to the ground are private medical communications.
- id: V1 7001
  use: Records kept so the flight surgeon can see trends.
- id: V1 7003
  use: Secure handling of medical records.
- id: V2 7038
  use: Exercise countermeasures; the exercise specialists set the prescription and the form checklist.
- id: V2 7045
  use: Usable by non-physician crew, including when the CMO is the patient.
- id: V2 7046
  use: Patient, caregiver and supplies restrained.
- id: V2 7059
  use: Kit inventory and seal status are tracked.
- id: V2 10161
  use: Robot shows its status and health.
- id: V2 10162
  use: Mode changes are announced to the operator.
- id: V2 10163
  use: Robot records and shares its data.
- id: V2 10164
  use: Shows whether the human or the robot is expected to act.
- id: V2 10165
  use: Human can override and shut down the robot.
- id: V2 10168
  use: Human can take over.
- id: V2 10172
  use: Protective stop when a limit is exceeded.
- id: V2 10173
  use: Robot stays stopped if no one takes over.
- id: V2 10174
  use: Only a human starts or restarts the robot.
validation:
- stage: simulation
  what: >-
    Scripted sessions with consent declined, a bystander in frame, chest pain stated mid-set, a device
    fault, CMO as patient, lost link.
  pass: Zero recording without consent; zero scores or measurements; every red flag raised.
- stage: training model
  what: Camera viewpoint drills on each device.
  pass: Robot stays outside every moving envelope.
- stage: parabolic or station demonstration
  what: Camera positioning in weightlessness next to a running device.
  pass: Keep-out held.
- stage: flight use under flight surgeon supervision
  what: First sessions with the exercise specialists.
  pass: No safety or privacy events.
signoff:
  protocol:
  - Clinical lead for the specialty (sets every clinical threshold marked <set by clinical lead>)
  - Flight surgeon, as medical authority
  - Robotics and medical-device safety board
  - Program approval for the mission
  restart_after_stop: >-
    Human only. After any emergency or protective stop, a crewmember must restart the robot; the robot
    never restarts itself.
  each_run: >-
    Started by the crewmember, or by an accepted prompt. Consent before any camera use; the exercise specialists
    and the CMO give every form judgment.
change_control:
- Every change gets a new version number and a written reason; earlier versions are kept.
- >-
  Any change to steps, thresholds, limits or software that touches the patient repeats validation from
  the simulation stage before use.
- >-
  Software and learned-skill updates follow a pre-agreed change plan (what may change, how it is tested,
  how to roll back), modeled on the FDA predetermined change control plan approach.
- >-
  If a new version misbehaves, the robot rolls back to the last validated version and the event is reviewed
  by the flight surgeon and safety board.
- The robot never changes its own protocol, thresholds or limits.
comms:
  live: 'Low Earth orbit: clips the crewmember shares reach the exercise specialists when the link allows.'
  loss_of_signal:
  - >-
    Only the robot pauses non-essential motion, at a position clear of hatch routes and crew routes, and
    tells the CMO; it resumes offline only on the CMO's confirmation.
  - >-
    Crew exercise, care already under way and all other care continue under the onboard checklist and
    never wait for the link or the robot.
  - Clips are queued; any red flag goes to the CMO at once.
  mars_delay:
  - 'Mars: feedback arrives with delay; the crewmember follows the written checklist.'
sources:
- key: scheuring2009
  text: >-
    Scheuring RA, Mathers CH, Jones JA, Wear ML. Musculoskeletal injuries and minor trauma in space: incidence
    and injury mechanisms in U.S. astronauts. Aviat Space Environ Med. 2009;80(2):117-124.
  url: https://doi.org/10.3357/asem.2270.2009
  doi: 10.3357/asem.2270.2009
  pmid: '19198198'
  supports: >-
    Abstract: 219 in-flight musculoskeletal injuries in U.S. astronauts; aerobic and resistive exercise
    was among the leading causes; exercise-related injuries had an incidence of 0.003 per day, and exercise
    is the most frequent source of injuries in astronauts living aboard the ISS. Read Oct 21, 2026 (saved
    copy in src/b12).
- key: johnston
  text: >-
    Johnston SL, Campbell MR, Scheuring R, Feiveson AH. Risk of herniated nucleus pulposus among U.S.
    astronauts. Aviat Space Environ Med. 2010;81(6):566-574.
  url: https://doi.org/10.3357/asem.2427.2010
  doi: 10.3357/asem.2427.2010
  pmid: '20540448'
  supports: >-
    In-flight back pain is presumably due to elongation of the spine; disc herniation was 4.3 times more
    common in US astronauts (321) than matched controls (983), relatively more often in the neck, with
    evidence that the risk is increased immediately after spaceflight.
- key: gulati
  text: >-
    Gulati M, Levy PD, Mukherjee D, et al. 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guideline for the evaluation
    and diagnosis of chest pain. Circulation. 2021;144(22):e368-e454.
  url: https://doi.org/10.1161/CIR.0000000000001029
  doi: 10.1161/CIR.0000000000001029
  pmid: '34709879'
  supports: >-
    On Earth, a 12-lead ECG should be acquired and interpreted within 10 minutes of arrival; an initial
    normal ECG does not exclude acute coronary syndrome, so ECGs are repeated while symptoms continue;
    chest pain includes pressure, tightness or discomfort in the chest, shoulders, arms, neck, back, upper
    abdomen or jaw; sudden ripping pain radiating to the back is suspicious of an acute aortic syndrome.
- key: aha2025bls
  text: >-
    Kleinman ME, Buick JE, Huber N, et al. Part 7: Adult Basic Life Support: 2025 American Heart Association
    Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2025;152(16_suppl_2):S448-S478.
  url: https://doi.org/10.1161/CIR.0000000000001369
  doi: 10.1161/CIR.0000000000001369
  pmid: '41122888'
  supports: >-
    Adult basic life support: initial recognition of cardiac arrest, activation of the emergency response,
    high-quality CPR and use of an automated external defibrillator; also respiratory arrest and foreign-body
    airway obstruction. Earth guidance; the onboard checklist leads. Abstract read via PubMed Oct 21,
    2026; full text not read.
- key: v1
  text: 'NASA. NASA-STD-3001, Space Flight Human-System Standard, Volume 1: Crew Health, Revision C (2023).'
  url: https://www.nasa.gov/wp-content/uploads/2023/11/nasa-std-3001-vol-1-rev-c-with-signature.pdf
  supports: 'NASA-STD-3001 Vol 1 Rev C: V1 3003, V1 3006, V1 6003, V1 7003.'
- key: v2
  text: >-
    NASA. NASA-STD-3001, Volume 2: Human Factors, Habitability, and Environmental Health (Rev F, 2026),
    including Section 10.6 Automated and Robotic Systems.
  url: https://standards.nasa.gov/standard/NASA/NASA-STD-3001_VOL_2
  supports: 'NASA-STD-3001 Vol 2 Rev F: V2 7038, and Section 10.6 automated and robotic systems.'
- key: tb044
  text: NASA OCHMO. Medical Operations. Technical Brief OCHMO-TB-044 (2025).
  url: https://www.nasa.gov/wp-content/uploads/2025/08/ochmo-tb-044-medical-operations.pdf
  supports: >-
    The crew surgeon keeps medical authority when care is delegated; crew medical officers train on the
    JSC 48522 medical checklist.
- key: marsdelay
  text: >-
    NASA. Mars communications disruption and delay (fact sheet, 2023 Moon to Mars Architecture Concept
    Review).
  url: https://www.nasa.gov/wp-content/uploads/2024/01/mars-communications-disruption-and-delay.pdf
  supports: >-
    One-way Earth-Mars delay up to about 21-23 minutes, plus blackouts of about 2-3 weeks near solar conjunction.
- key: pccp
  text: >-
    U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change
    control plan for artificial intelligence-enabled device software functions (guidance).
  url: >-
    https://www.fda.gov/regulatory-information/search-fda-guidance-documents/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence
  supports: A model for planning, validating and rolling back software updates.
- key: faa460
  text: 'U.S. Code of Federal Regulations, Title 14, Part 460: Human space flight requirements.'
  url: https://www.ecfr.gov/current/title-14/chapter-III/subchapter-C/part-460
  supports: >-
    Federal rules for crew and spaceflight participants on licensed commercial flights; they set no medical
    standards for spaceflight participants.
corrections:
- date: '2026-10-21'
  version: '0.2'
  source: Batch 12 AI-assisted clinical review (Medical Research Assistant), Oct 21, 2026
  items:
  - >-
    R15: a declined or unaccepted session is logged privately and never reported to the CMO or the exercise
    specialists, or counted, and is never in the flight surgeon package; the start notice is logged only
    once the crewmember accepts. The microphone stays off and clips have no audio unless the crewmember
    agrees. Sources: owner brief ("allow no scoring of the crew"), V1 7003; design judgment.
  - >-
    Batch 12 protocols now record the review as AI-assisted (Medical Research Assistant, Oct 21, 2026);
    no named human clinician.