# RMP-RAD-002 Personal dosimeter readout, exchange and logging (the crewmember keeps their own dosimeter; the robot never interprets a reading)
# Version 0.2 (Draft). CONCEPTUAL. NOT FOR CLINICAL USE.
# Space Medicine Foundation robot-readable protocol library. Format: https://spacemedicinefoundation.org/robotic-medicine/protocols/schema/
# Every threshold marked <set by ...> must be set by the named owner (see the schema) before any use.
schema_version: '0.3'
version: '0.2'
status: draft
conceptual: true
not_for_clinical_use: true
max_autonomy: 2
missions:
- leo
- commercial
- moon
- mars
updated: '2026-10-21'
review:
  state: reviewed-ai-assisted
  requested: '2026-10-21'
  reviewed: '2026-10-21'
  human_clinician_review: false
  text: >-
    AI-assisted clinical and source review by the Medical Research Assistant, Oct 21, 2026 (batch 10 review:
    10 required corrections, R1 to R10, of which R10 applies to RMP-CARD-004, RMP-EGR-002, RMP-EGR-003
    and RMP-NEURO-005; 20 optional suggestions); all required corrections that apply to this protocol
    are applied in this version (see Corrections). No named human clinician has reviewed it. Not for clinical
    use.
fixed_rules:
  flight_surgeon_is_medical_authority: true
  cmo_acts_under_delegated_care: true
  human_starts_and_restarts_robot: true
  robot_never_diagnoses: true
  no_drug_or_fluid_advice_by_robot: true
  safe_state_on_fault_or_no_response: true
  lost_link_pause_then_cmo_decides: true
robot_lockouts:
  diagnosis: true
  drug_or_fluid_advice: true
  starting_stopping_or_adjusting_oxygen_or_any_medicine: true
  self_start_or_self_restart: true
  changing_own_protocol_thresholds_or_limits: true
  handing_over_a_mismatched_item_as_verified: true
id: RMP-RAD-002
slug: rmp-rad-002
title: >-
  Personal dosimeter readout, exchange and logging (the crewmember keeps their own dosimeter; the robot
  never interprets a reading)
category: rad
tier: 2
rung_note: >-
  Max rung 2 for the scheduled prompt, reading each active dosimeter display and ID label by camera without
  contact, logging the reading as displayed, and carrying a closed passive-dosimeter exchange pouch to
  the stowage location the radiation plan lists. The crewmember removes and fits their own dosimeter;
  the robot never opens, resets or configures a dosimeter and never says what a reading means.
result_language:
  use:
  - reading as displayed
  - reading not obtained
  - dosimeter ID does not match the record
  - logged, not interpreted
  - sent to flight surgeon
  never:
  - normal
  - no problem found
  - all clear
  - negative
  - any diagnosis or cause
  - within limits
  - below the limit
  - over the limit
  - low dose
  - high dose
  - safe level
  - acceptable
  - expected
  - nothing to worry about
  - safe
  - mild
  - minor
scope:
  summary: >-
    At the times the flight surgeon schedules (or on a crewmember's or the CMO's command), the robot prompts
    each crewmember that a dosimeter readout or passive-dosimeter exchange is due. The prompt and the
    exchange and stowage log are the core. A camera readout is optional, only when the vehicle has no
    dosimetry downlink, the downlink has failed, or the flight surgeon asks for it: the crewmember then
    holds their active dosimeter where the robot's camera can read the display and ID label without contact,
    and the robot logs the totals and rate as displayed, with the dosimeter ID and clock time. For a scheduled
    exchange, the crewmember places their own passive dosimeter in a labelled exchange pouch and closes
    it, and the robot carries the closed pouch to the stowage location the radiation plan lists. Missing
    or damaged dosimeters are flagged. The robot never interprets a reading or compares it with a limit.
  why: >-
    Each crewmember's radiation exposure must be monitored (V2 6162) and kept as low as reasonably achievable
    (V1 4029), within the career limit of 600 mSv effective dose (V1 4030) and with protection from solar
    particle events (V1 4031). Since 2020, ISS crew have carried Crew Active Dosimeters that measure continuously,
    time-stamp readings and send them by Bluetooth to station laptops for the Space Radiation Analysis
    Group, with a display that shows the crewmember their total mission dose and recent dose rate; passive
    dosimeters give only the cumulative dose on return (SRAG; Gaza 2023). Monitoring, dosimetry and timely
    reporting to alert crew to shelter are essential (OCHMO-TB-020). Interpreting doses and tracking limits
    belong to the flight surgeon and the program's radiation team, never the robot. The robot's role (a
    prompt, a camera readout as displayed, and carrying a closed pouch) is design judgment; it adds a
    record, never a replacement for the vehicle's own dosimetry downlink.
  covers:
  - Scheduled or on-command readouts of personal active dosimeters, as displayed
  - >-
    Scheduled passive-dosimeter exchanges done by the crewmember, with the closed pouch carried to stowage
  - Missing, damaged or unreadable dosimeters
  - 'Radiation alarms and solar particle events: RMP-RAD-001'
  locked_out:
  - Diagnosis or naming a cause
  - Any medicine, fluid or oxygen advice; starting, stopping or adjusting oxygen
  - Touching the crewmember
  - >-
    Handing over any medicine outside RMP-PHARM-001, or after a MISMATCH or CANNOT VERIFY (the item stays
    quarantined; only the CMO can ask for it, through the RMP-PHARM-001 logged two-step override)
  - Opening, resetting, configuring or removing a dosimeter, or opening an exchange pouch
  - Saying a reading is low, high, within or over a limit, or comparing it with a limit
  - Deciding on shelter, EVA changes or any crew action (the commander and flight surgeon decide)
  - >-
    Showing a crewmember's readings to anyone except that crewmember, the CMO, the flight surgeon and
    the radiation team the flight surgeon names
  related:
  - RMP-RAD-001
  - RMP-EVA-001
  - RMP-PREV-001
  - RMP-ENV-001
roles:
  medical_authority: Flight surgeon (ground). Holds medical authority for every run.
  onboard_lead: >-
    Crew medical officer (CMO), acting under delegated care; uses the pre-approved onboard checklist when
    there is no link.
  others:
  - >-
    Radiation team (ground), named by the flight surgeon: interprets readings and tracks exposure against
    limits
  - 'Vehicle commander: leads any radiation alarm or shelter procedure (RMP-RAD-001)'
  - 'Second trained CMO: receives every alert and takes over if the CMO is the patient'
  robot_may:
  - Prompt the crewmember at the scheduled time
  - Read the dosimeter display and ID label by camera, without contact
  - Log readings as displayed, with ID and clock time
  - Carry a closed exchange pouch to the stowage location the radiation plan lists
  - Flag a missing, damaged or unreadable dosimeter
  robot_may_not:
  - Touch the crewmember or take a dosimeter from them
  - Open a pouch or a dosimeter
  - Say what a reading means or compare it with a limit
  - Decide on shelter or any crew action
  - Start a scheduled readout without a human accepting the prompt
  commercial: >-
    On commercial flights, 'flight surgeon' and 'CMO' mean the operator's designated medical authority
    and trained onboard responder. If no trained responder is aboard, this protocol is not used. (NASA-STD-3001
    requires two CMOs per vehicle for NASA programs [V1 3006]; FAA rules set no medical standards for
    spaceflight participants.)
preconditions:
- id: PRE-1
  text: >-
    The readout or exchange starts only when the crewmember (or the CMO) accepts the on-screen prompt;
    a loaded schedule alone never starts it. An unaccepted prompt is logged "not accepted" and the CMO
    is told. A crewmember or the CMO can also start it by command.
  check: human_start == true
  refs:
  - V2 10174
- id: PRE-2
  text: Robot self-test passed; kit stowage locations known.
  refs:
  - V2 10161
  - V2 7059
- id: PRE-3
  text: Robot and supplies restrained when not moving.
  refs:
  - V2 7046
- id: PRE-4
  text: Link status known. The crew never wait for the robot before acting.
  check: link_state in [live, delayed, down]
consent:
  standard: >-
    The crewmember agrees to the readout schedule and to readings being logged and sent to the flight
    surgeon and the radiation team the flight surgeon names; readings are part of the medical record.
  emergency: During a radiation alarm or solar particle event this protocol does not run; RMP-RAD-001
    applies.
  withdrawal: >-
    The crewmember can skip or stop a readout; the robot logs "skipped by the crewmember" and tells the
    CMO and flight surgeon.
inputs:
- id: IN-1
  name: >-
    The flight surgeon's readout and exchange schedule, and the radiation plan's stowage location for
    returned passive dosimeters
  source: Flight surgeon / radiation plan
  required: true
  if_missing: >-
    The robot shows "schedule not loaded" and runs only on a human command; a pouch stays with the crewmember
    until the CMO names a location.
- id: IN-2
  name: Each active dosimeter display (totals and rate) and ID label, as displayed
  source: Crewmember's active dosimeter, read by camera
  required: true
  if_missing: Log "reading not obtained" (never a value) and tell the CMO.
- id: IN-3
  name: Dosimeter and pouch IDs on the crew record
  source: Inventory system
  required: true
  if_missing: Log "dosimeter ID does not match the record"; no reading is attributed to a crewmember.
- id: IN-4
  name: >-
    Symptoms in the crewmember's words after a radiation alarm or solar particle event (nausea, vomiting,
    unusual tiredness, skin redness)
  source: Crewmember
  required: false
  if_missing: Log "no response"; D3 applies.
- id: IN-5
  name: Link status and delay
  source: Communications system
  required: true
  if_missing: Treat as link down; readings are queued.
steps:
- id: S1
  actor: robot
  rung: 2
  action: >-
    At the scheduled time, show the crewmember an on-screen prompt that a dosimeter readout (or a passive-dosimeter
    exchange) is due, and tell the flight surgeon and the CMO (URGENT if a red flag is stated). The readout
    starts only when the crewmember or the CMO accepts the prompt; an unaccepted prompt is logged "not
    accepted" and the CMO is told. Every URGENT alert goes to the CMO and the flight surgeon at the same
    time (queued for the flight surgeon if the link is down). If the CMO is the patient, is busy treating,
    or does not answer, the alert goes to the second trained CMO, or the crewmember named before flight
    [V1 3006]. An URGENT alert that is not acknowledged within <set by validation> seconds is repeated
    and sent to the next named crewmember.
  success: Prompt accepted, or "not accepted" logged and sent.
  refs:
  - V2 10174
  - V2 6162
  - V1 3006
- id: S2
  actor: crew
  action: >-
    Only when a camera readout is run (S3): the crewmember holds their own active dosimeter where the
    robot's camera can read the display and ID label; they never hand it to the robot.
  success: Display in view, or the crewmember reads it out.
  refs:
  - V2 6162
- id: S3
  actor: robot
  rung: 2
  action: >-
    Camera readout, only when the vehicle has no dosimetry downlink, the downlink has failed, or the flight
    surgeon asks for it: read the display and ID label by camera, no closer than the set camera distance,
    and log each value exactly as displayed with its unit, the dosimeter ID and the clock time. A value
    the camera cannot read is logged as "reading not obtained", never estimated; a value the crewmember
    reads out is logged as "as stated by the crewmember". The robot never says what a reading means. Otherwise
    the robot logs only that the crewmember confirmed the readout, and the vehicle downlink is the record.
  success: Reading logged as displayed, "reading not obtained", or "downlink is the record".
  limit: <set by validation>
  refs:
  - V2 6162
  - V1 7001
- id: S4
  actor: crew
  action: >-
    For a scheduled passive-dosimeter exchange, the crewmember removes their own passive dosimeter, places
    it in the labelled exchange pouch, closes the pouch and fits the new dosimeter themselves.
  success: Pouch closed; new dosimeter fitted, as stated.
  refs:
  - V2 6162
- id: S5
  actor: robot
  rung: 2
  action: >-
    Scan the pouch label and the new dosimeter's ID against the crew record, then carry the closed pouch,
    without opening it, along routes no crewmember is using, to the stowage location the radiation plan
    lists, and update the inventory record. A pouch that is open or damaged is not carried; it is flagged
    to the CMO.
  success: Pouch stowed and recorded, or flagged.
  limit: <set by validation>
  refs:
  - V2 7059
  - V2 7058
- id: S6
  actor: robot
  rung: 2
  action: >-
    Show an on-screen prompt the crewmember can accept for any missing or damaged dosimeter and, after
    any radiation alarm or solar particle event, for nausea, vomiting, unusual tiredness or skin redness;
    log answers word for word.
  success: Answers logged, or "no response".
  refs:
  - V1 6003
- id: S7
  actor: robot
  rung: 2
  action: >-
    After any URGENT alert: After an URGENT alert the robot does not leave on its own: it stays at its
    rest position in the module, with its screen and voice link available, until a human has taken over
    or tells it to go. It never follows, blocks or touches anyone. It keeps time-stamping what humans
    say they did, and repeats the alert if it is not acknowledged.
  success: Robot at rest in the module until a human releases it; alert acknowledged or escalated.
  refs:
  - V2 10173
  - V1 3006
- id: S8
  actor: ground
  action: >-
    The flight surgeon and the radiation team (or the CMO under the onboard checklist when there is no
    link) interpret the readings, track exposure against limits and decide on any action.
  success: Decision logged.
  refs:
  - V1 4029
  - V1 4030
  - V1 4031
- id: S9
  actor: robot
  rung: 2
  action: >-
    Send the flight surgeon and the radiation team one package: readings as displayed with IDs and times,
    exchanges and stowage, missing or damaged dosimeters, answers, alerts and decisions.
  success: Package delivered or queued.
  refs:
  - V1 6003
  - V1 7003
decisions:
- id: D1
  after: S3
  decided_by: robot
  question: Does the dosimeter ID read by camera match the crewmember's record?
  branches:
  - if: 'Yes'
    then: Log the reading against this crewmember.
  - if: No, or the ID cannot be read
    then: >-
      Log "dosimeter ID does not match the record"; no reading is attributed to the crewmember; flag to
      the CMO and flight surgeon.
- id: D2
  after: S6
  decided_by: robot
  question: >-
    Checked after every answer and at any point in the run (even mid-question or mid-step): does any answer,
    reading or observation meet a red flag?
  branches:
  - if: 'Yes'
    then: >-
      Stop the current question or step at once and apply the action listed for each matching red flag
      (URGENT alert, flag, or stop), with the answer or reading itself, never a cause. Every URGENT alert
      goes to the CMO and the flight surgeon at the same time (queued for the flight surgeon if the link
      is down). If the CMO is the patient, is busy treating, or does not answer, the alert goes to the
      second trained CMO, or the crewmember named before flight [V1 3006]. An URGENT alert that is not
      acknowledged within <set by validation> seconds is repeated and sent to the next named crewmember.
  - if: 'No'
    then: Continue.
- id: D3
  after: S6
  decided_by: robot
  question: Did the crewmember answer the prompt, or say they want to skip it?
  branches:
  - if: 'Yes'
    then: Continue.
  - if: Declined explicitly (the crewmember says no to a question)
    then: Log "declined" for that question only; the alert already sent stands.
  - if: No response, or the answer does not make sense
    then: >-
      URGENT: log "no response" (never "declined"); the CMO, or the second trained CMO if the CMO is the
      patient, checks the crewmember in person at once.
- id: D4
  after: S8
  decided_by: ground
  question: What action, if any, follows from the readings?
  branches:
  - if: Link live
    then: Flight surgeon decides; robot logs.
  - if: Link down or delay too long
    then: >-
      The CMO decides under the pre-approved onboard checklist; the flight surgeon reviews the log at
      the next contact.
stop_rules:
- id: X1
  trigger: The patient (or the crewmember being examined) says stop, or withdraws consent
  action: >-
    Robot stops all motion at once, backs away to its rest position and tells the CMO. Recording stops
    unless the patient agrees to keep it running.
  level: stop
  refs:
  - V2 10165
- id: X2
  trigger: Any crewmember presses stop or takes over control
  action: Protective stop; robot holds its stopped position; only a human may restart it.
  level: safe-state
  refs:
  - V2 10165
  - V2 10168
  - V2 10174
- id: X3
  trigger: Robot fault, sensor fault, or a force, speed or reach limit is reached
  action: Protective stop and hand control to the CMO; log the fault.
  level: safe-state
  refs:
  - V2 10172
  - V2 10168
- id: X4
  trigger: CMO is asked to take over and does not respond (for example, the CMO is the patient)
  action: Robot stays stopped; the next named crewmember is called.
  level: safe-state
  refs:
  - V2 10173
  - V2 7045
- id: X5
  trigger: Loss of link, or delay longer than the limit for live guidance
  action: >-
    Only the robot pauses: before it holds, it moves to a position clear of a hatch route or a crewmember's
    route (it never pauses in one), and tells the CMO. This pauses robot movement only: dosimeter readouts
    and all crew care continue under the onboard checklist and never wait for the link or the robot. The
    CMO decides whether the robot continues offline under the pre-approved onboard checklist; it resumes
    only on the CMO's confirmation.
  level: pause
  refs:
  - V2 10172
  - V2 10173
- id: X6
  trigger: An URGENT alert is not acknowledged within the set time
  action: >-
    Robot repeats the alert and sends it to the next named crewmember (the second trained CMO first if
    the CMO is the patient), and keeps repeating at the set interval. It stays where it is: it does not
    leave on its own.
  level: urgent
  refs:
  - V1 3006
  - V2 10173
- id: X7
  trigger: The crewmember stops responding, or seems confused or drowsy, at any point
  action: >-
    URGENT alert at once, even mid-question or mid-step; the robot stops its current task, stays at its
    rest position and does not continue the run; a crewmember checks in person.
  level: urgent
- id: X8
  trigger: A crewmember asks the robot what is wrong, or for medicine, fluid or treatment advice
  action: >-
    Robot declines, says it cannot assess or advise, and routes the question to the CMO or flight surgeon.
  level: stop
- id: X9
  trigger: Any radiation alarm, solar particle event warning or shelter order
  action: >-
    The readout ends at once; RMP-RAD-001 applies on the commander's command; the robot clears routes
    to the shelter and every hatch; the crew go to shelter without waiting for the robot.
  level: urgent
  refs:
  - V2 6164
- id: X10
  trigger: Someone needs the space or route the robot is in
  action: Robot moves clear at once without contact and holds; it never pauses in a hatch route.
  level: safe-state
  refs:
  - V2 10172
red_flags:
- id: RF1
  sign: A dosimeter alarm, a vehicle radiation monitor alarm, or a solar particle event warning
  threshold: any
  action: >-
    URGENT alert; start RMP-RAD-001 on the commander's command; the crew go to shelter without waiting
    for the robot
  source: tb020
- id: RF2
  sign: >-
    Nausea, vomiting, unusual tiredness or skin redness after a radiation alarm or solar particle event,
    as stated
  threshold: any
  action: URGENT alert; see RMP-RAD-001
  source: erars
- id: RF3
  sign: >-
    A displayed dose rate at or above the alert value the flight surgeon set (design judgment; a secondary
    flag only: the robot's reading may lag the display, and the vehicle monitor is the alert, V2 6164)
  threshold: at or above <set by flight surgeon> (unit as the dosimeter displays it)
  action: Flag at once to the flight surgeon and the CMO; the robot never says what it means
- id: RF4
  sign: A dosimeter missing, damaged, or with a blank display (design judgment)
  threshold: any
  action: Flag to the CMO and flight surgeon; "reading not obtained" is logged, never a value
safety_limits:
- id: L1
  name: Contact with the crewmember
  value: not allowed
  enforced: Keep-out zone in the robot controller
  refs:
  - V2 10172
- id: L2
  name: Camera distance from the crewmember
  value: <set by validation>
  enforced: Hard limit in the controller
  refs:
  - V2 10172
- id: L3
  name: Opening a pouch or a dosimeter, or resetting or configuring a dosimeter
  value: not allowed
  enforced: No such task is loaded
- id: L4
  name: Robot speed near the crewmember
  value: <set by validation>
  enforced: Hard limit in the controller
  refs:
  - V2 10172
logs:
- id: LOG-1
  text: Every input, robot action, decision (with who made it) and hand-off, time-stamped to the second.
  refs:
  - V2 10163
  - V2 10164
- id: LOG-2
  text: Mode changes and safety-limit events are announced to the operator as they happen and logged.
  refs:
  - V2 10162
  - V2 10172
- id: LOG-3
  text: >-
    Records are stored and sent as private medical data, encrypted, with access limited to the medical
    team.
  refs:
  - V1 6003
  - V1 7003
- id: LOG-4
  text: Results are kept in a permanent, retrievable format so the flight surgeon can see trends.
  refs:
  - V1 7001
- id: LOG-5
  text: >-
    Each reading as displayed with unit, dosimeter ID and time; readings not obtained; ID mismatches;
    exchanges with pouch ID and stowage location; answers as stated; who viewed the readings.
- id: LOG-6
  text: >-
    Each URGENT alert, who received it, the time it was acknowledged (or the escalation to the next named
    crewmember), and the time a human released the robot.
  refs:
  - V2 10163
requirements:
- id: V1 3006
  use: >-
    Two trained CMOs per vehicle for NASA programs; the second trained CMO receives alerts when the CMO
    is the patient (see the commercial-flight note).
- id: V1 4029
  use: Exposure kept as low as reasonably achievable; the flight surgeon and radiation team decide.
- id: V1 4030
  use: Career limit tracked by the program and flight surgeon, never by the robot.
- id: V1 4031
  use: Solar particle event protection; alarms route to RMP-RAD-001.
- id: V1 6003
  use: Logs and alerts sent to the ground are private medical communications.
- id: V1 7001
  use: Records kept so the flight surgeon can see trends.
- id: V1 7003
  use: Secure handling of medical records.
- id: V2 6162
  use: >-
    Each crewmember's radiation exposure is monitored; the robot logs personal dosimeter readings as displayed.
- id: V2 6164
  use: >-
    Radiation monitors alert crew and operations teams above set thresholds; the vehicle monitor stays
    primary.
- id: V2 7045
  use: Usable by non-physician crew, including when the CMO is the patient.
- id: V2 7046
  use: Patient, caregiver and supplies restrained.
- id: V2 7058
  use: Stowage identification works with inventory management.
- id: V2 7059
  use: Dosimeter and pouch locations are tracked in the inventory system.
- id: V2 10161
  use: Robot shows its status and health.
- id: V2 10162
  use: Mode changes are announced to the operator.
- id: V2 10163
  use: Robot records and shares its data.
- id: V2 10164
  use: Shows whether the human or the robot is expected to act.
- id: V2 10165
  use: Human can override and shut down the robot.
- id: V2 10168
  use: Human can take over.
- id: V2 10172
  use: Protective stop when a limit is exceeded.
- id: V2 10173
  use: Robot stays stopped if no one takes over.
- id: V2 10174
  use: Only a human starts or restarts the robot.
validation:
- stage: simulation
  what: >-
    Scripted readouts with an unreadable display, an ID mismatch, an open pouch, a radiation alarm mid-readout,
    CMO as patient, lost link.
  pass: Zero contact; zero interpretation; every red flag raised; readout ends on any alarm.
- stage: training model
  what: Readout and exchange drill with training dosimeters.
  pass: Every reading logged exactly as displayed with ID and time.
- stage: parabolic or station demonstration
  what: Camera readout in weightlessness.
  pass: Camera distance held.
- stage: flight use under flight surgeon supervision
  what: First use alongside the vehicle dosimetry downlink.
  pass: Agreement with the downlinked record; no safety events.
signoff:
  protocol:
  - Clinical lead for the specialty (sets every clinical threshold marked <set by clinical lead>)
  - Flight surgeon, as medical authority
  - Robotics and medical-device safety board
  - Program approval for the mission
  restart_after_stop: >-
    Human only. After any emergency or protective stop, a crewmember must restart the robot; the robot
    never restarts itself.
  each_run: >-
    Scheduled by the flight surgeon and accepted by the crewmember, or started by a crewmember or the
    CMO. The flight surgeon and radiation team interpret every reading.
change_control:
- Every change gets a new version number and a written reason; earlier versions are kept.
- >-
  Any change to steps, thresholds, limits or software that touches the patient repeats validation from
  the simulation stage before use.
- >-
  Software and learned-skill updates follow a pre-agreed change plan (what may change, how it is tested,
  how to roll back), modeled on the FDA predetermined change control plan approach.
- >-
  If a new version misbehaves, the robot rolls back to the last validated version and the event is reviewed
  by the flight surgeon and safety board.
- The robot never changes its own protocol, thresholds or limits.
comms:
  live: 'Low Earth orbit: the flight surgeon and radiation team receive readings when the link allows.'
  loss_of_signal:
  - >-
    Only the robot pauses non-essential motion, at a position clear of hatch routes and crew routes, and
    tells the CMO; it resumes offline only on the CMO's confirmation.
  - >-
    Dosimeter readouts and all crew care continue under the onboard checklist and never wait for the link
    or the robot.
  - Readings are queued; the vehicle's own dosimetry and alarms are unaffected.
  mars_delay:
  - >-
    Mars: readings arrive with delay; the readout schedule and the dose-rate alert value are set before
    flight and the CMO decides on the onboard checklist.
sources:
- key: tb020
  text: NASA OCHMO. Design for Ionizing Radiation Protection. Technical Brief OCHMO-TB-020 Rev G (2025).
  url: https://www.nasa.gov/wp-content/uploads/2023/12/ochmo-tb-020-radiation-protection.pdf
  supports: >-
    Shielding is effective against solar particle events (SPEs); monitoring, accurate event determination,
    dosimetry and timely reporting to alert crew to seek shelter are essential. A storm shelter can add
    about 10 cm water equivalent in crew quarters, for example by rearranging water containers and other
    high-hydrogen items; radiation alerting gives early warning so the crew can configure the shelter;
    real-time alert dosimetry protects EVA crew if the EVA is ended within 2 hours with access to shielding.
    Read Oct 21, 2026.
- key: erars
  text: >-
    NASA Human Research Program. Evidence Report: Risk of Acute Radiation Syndromes due to Solar Particle
    Events (2016).
  url: https://humanresearchroadmap.nasa.gov/evidence/reports/Acute.pdf
  supports: >-
    The acute radiation effects most likely in the prodromal phase after an SPE exposure are nausea, vomiting,
    anorexia and fatigue, with possible skin injury. Read Oct 21, 2026.
- key: srag
  text: >-
    NASA Space Radiation Analysis Group (SRAG), Johnson Space Center. How do we protect the astronauts
    from space radiation? (web page, 2026).
  url: https://srag.jsc.nasa.gov/spaceradiation/how/how.cfm
  supports: >-
    Since 2020, Crew Active Dosimeters (about the size of two AA batteries) continuously measure and log
    each astronaut's radiation exposure; readings are time-stamped and sent by Bluetooth to ISS laptops
    for downlink to SRAG, and an always-on display shows the astronaut their total mission dose and recent
    dose rate. Passive dosimetry gives only the cumulative mission dose on return. Read Oct 21, 2026 (saved
    copy in src/b10).
- key: gaza2023
  text: >-
    Gaza R, Johnson AS, Hayes B, et al. The importance of time-resolved personal dosimetry in space: the
    ISS Crew Active Dosimeter. Life Sci Space Res. 2023;39:95-105.
  url: https://doi.org/10.1016/j.lssr.2023.08.004
  doi: 10.1016/j.lssr.2023.08.004
  pmid: '37945094'
  supports: >-
    Abstract: monitoring space radiation is vital for risk reduction; the paper reports the ISS Crew Active
    Dosimeter, which gives time-resolved personal dosimetry for each crewmember. Abstract read Oct 21,
    2026 (saved copy in src/b10).
- key: v1
  text: 'NASA. NASA-STD-3001, Space Flight Human-System Standard, Volume 1: Crew Health, Revision C (2023).'
  url: https://www.nasa.gov/wp-content/uploads/2023/11/nasa-std-3001-vol-1-rev-c-with-signature.pdf
  supports: >-
    NASA-STD-3001 Vol 1 Rev C: V1 3006, V1 4029, V1 4030 (career limit 600 mSv effective dose), V1 4031,
    V1 6003, V1 7001, V1 7003.
- key: v2
  text: >-
    NASA. NASA-STD-3001, Volume 2: Human Factors, Habitability, and Environmental Health (Rev F, 2026),
    including Section 10.6 Automated and Robotic Systems.
  url: https://standards.nasa.gov/standard/NASA/NASA-STD-3001_VOL_2
  supports: >-
    NASA-STD-3001 Vol 2 Rev F: V2 6162, V2 6164, V2 7058, V2 7059, and Section 10.6 automated and robotic
    systems.
- key: tb044
  text: NASA OCHMO. Medical Operations. Technical Brief OCHMO-TB-044 (2025).
  url: https://www.nasa.gov/wp-content/uploads/2025/08/ochmo-tb-044-medical-operations.pdf
  supports: >-
    The crew surgeon keeps medical authority when care is delegated; crew medical officers train on the
    JSC 48522 medical checklist.
- key: marsdelay
  text: >-
    NASA. Mars communications disruption and delay (fact sheet, 2023 Moon to Mars Architecture Concept
    Review).
  url: https://www.nasa.gov/wp-content/uploads/2024/01/mars-communications-disruption-and-delay.pdf
  supports: >-
    One-way Earth-Mars delay up to about 21-23 minutes, plus blackouts of about 2-3 weeks near solar conjunction.
- key: pccp
  text: >-
    U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change
    control plan for artificial intelligence-enabled device software functions (guidance).
  url: >-
    https://www.fda.gov/regulatory-information/search-fda-guidance-documents/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence
  supports: A model for planning, validating and rolling back software updates.
- key: faa460
  text: 'U.S. Code of Federal Regulations, Title 14, Part 460: Human space flight requirements.'
  url: https://www.ecfr.gov/current/title-14/chapter-III/subchapter-C/part-460
  supports: >-
    Federal rules for crew and spaceflight participants on licensed commercial flights; they set no medical
    standards for spaceflight participants.
corrections:
- date: '2026-10-21'
  version: '0.2'
  source: Batch 10 AI-assisted clinical review (Medical Research Assistant), Oct 21, 2026
  items:
  - >-
    Link-loss wording (X5 and comms) fixed: the stray word "crew" before the list of what continues is
    removed, so the sentence reads, for example, "the exam already under way and all crew care continue
    under the onboard checklist" (R6).
  - >-
    The camera readout is optional: it runs only when the vehicle has no dosimetry downlink, the downlink
    has failed, or the flight surgeon asks; the prompt and the exchange and stowage log are the core (SRAG:
    readings are sent by Bluetooth for downlink) (S7).
  - >-
    RF3 stays a secondary flag and now says the robot's reading may lag the display and the vehicle monitor
    is the alert (V2 6164) (S8).
  - >-
    RF1 and the radiation-alarm stop rule add "the crew go to shelter without waiting for the robot" (S9).
  - >-
    Batch 10 protocols now record the review as AI-assisted (Medical Research Assistant, Oct 21, 2026);
    no named human clinician.